RX01/LX01 SERIES RF POWER SUPPLY OPERATOR’S MANUAL
ANALOG INTERFACE CONNECTOR PIN LIST
PIN SIGNAL NAME DESCRIPTION
R301MKII
L301MKII, R/L601,
R/L1001, R/L2001,
R/L3001, R5001
Note:
Applicable to models R101MKII, L101MKII, R301MKII,
L301MKII, R/L601, R/L1001, R/L2001, R/L3001, and R5001
15 INTERLOCK-RTN Ground return for External Interlock (pin 2)
16 GNDI Ground return for pins 3,4,5,6,7,19. Internally connected to
chassis ground.
Connect to system controller common or ground reference
17 GNDI Ground return for pins 3,4,5,6,7,19. Internally connected to
chassis ground.
Connect to system controller common or ground reference
18 RFENABLED RET Ground return for pin 8 (RFENABLED* signal).
For units manufactured on or before July 30, 2005, this pin is
internally connected to chassis ground (GNDI).
For unit manufactured on August 1, 2005 and later, this pin may
be configured as internally connected to chassis ground (GNDI)
(factory default configuration) or isolated from chassis ground
(OEM custom configurations). Configuration is set at the
factory.
Connect to system controller common or ground reference.
19 RL-IN Remote Limit input. Analog input, 0 to +5VDC range. Use pin
16 or 17 (GNDI) for return reference.
Used in dual-bias or multiple power supply systems to fold-back
the power supply’s output power if reflected power is detected
by another power supply in the system. Output power folds
back in response to an external voltage applied to this input.
Foldback threshold is factory preset at +5.00VDC (Disabled).
Consult factory for assistance.
20 RL-OUT Remote Limit Output. Analog output, 0 to +10VDC range.
Buffered, high-speed, non-linearized directional coupler
reflected power signal. Return reference is pin 23.
Used on dual-bias or multiple power supply systems. Consult
factory for assistance.
21 PHASE External Phase Sensor Input. Analog Input, -10.0VDC to
+10.0VDC range.
Used in conjunction with the Variable Frequency Tuning (VFT)
feature. On VFT-enabled units with VFT Feedback Mode set to
“PHASE TUNE MODE +” or “PHASE TUNE MODE –“ the
volta
g
e si
g
nal from an external
p
hase detector is used to steer
Page 91