L2001 Specifications
Voltage: 190-264V, Single Phase or Three Phase (specify at time of order).
There are no transformer voltage taps to configure.
AC Mains
Input Power
Frequency: 47-63 HZ
Current: Single Phase: 20A Maximum
Overcurrent Protection:
Single Phase:
High Range: 0 to 2000 Watts into 50 Ohms
Low Range: 0 to 200 Watts into 50 Ohms
RF Output Connector:
0.5% Long Term, +/- 1 Watt
Three Phase: 15A Maximum
Power required: 3100VA Maximum
Rear Panel Circuit Breaker,
2x 1.5A ¼”x1-1/4” time-delay fuses.
Power Cord: 12/3 Type SOW, 6 foot length, with NEMA Type
L6-20P locking connector
Three Phase: 12/4 Type SOW, 6 foot length, with NEMA Type
L15-20P locking connector
Output: Power:
Maximum Reflected
Power:
200 Watts
Frequency: 100-460KHz, Variable, 1KHz steps, frequency
synthesized.
Leveling: Forward Power, Load (Net) Power,
External Feedback (RF or DC Probe)
Type N or HN, Customer Specified
Frequency Stability: 0.005% Short-term
Power Stability:
Output Impedance: 50 Ohms, +/-5 Ohms Nominal
Metering Accuracy:
(Forward Power)
+/- 3% of Reading
Temperature Coefficient: 0.25% per °C
Forward Power
Regulation:
+/- 1% into 50 Ohms
Load Tolerance: No oscillation or failure into a mismatch
condition.
Page 157
Seren IPS Inc.
6100220000 Rev. 1.09