RX01/LX01 SERIES RF POWER SUPPLY OPERATOR’S MANUAL
PROGRAMMABLE PARAMETER DETAILS
PARAMETER PARAMETER DETAIL APPLIES TO
Control Source: Selects the interface used as the control source for the RF power
supply.
Factory default setting: PANEL
All
Panel Control Selects the front panel keypad as the control source. RF ON/OFF
and power setpoint commands from the analog interface are
ignored. Serial interface commands, with the exception of the
“SERIAL” command, are ignored.
Line 2 of the front panel display shows “PANEL” as the control
source.
All
Analog Control Selects the analog interface as the control source. Front panel RF
ON and power setpoint commands are ignored. Serial commands,
with the exception of the “SERIAL” command, are ignored.
Note:
The front panel RF ON/OFF button can disable the RF
output.
Line 2 of the front panel display shows “ANALOG” as the control
source.
All
Serial Control Selects the serial interface as the control source. Front panel RF
ON and power setpoint commands are ignored. RF ON/OFF and
power setpoint commands from the analog interface are ignored.
Note:
The front panel RF ON/OFF button can disable the RF
output.
Selecting Serial Control enables access to the serial interface
parameters.
Line 2 of the front panel display shows “SERIAL” as the control
source.
All
Serial Interface
Protocol:
Selects the serial interface protocol. RS-232, RS-422, RS-485 4-
Wire, RS-485 2-Wire, MODBUS 2-Wire (2W), or MODBUS 4-
Wire (4W) may be selected.
When RS-485, RS-422, or MODBUS is selected, access to the
serial address parameter is enabled.
Factory default setting: RS-232.
All
Serial Address Selects the serial address for RS-422, RS-485, and MODBUS
serial communication protocols.
RS-422, RS-485 Address range: 00 to 99
MODBUS Address range: 1 to 247
Note: For RS-232 operation, the Serial Address must be set to
“99”
Factory default setting: 99
All
Serial Baud Rate: Selects 2400, 4800, 9600, 19200, 38400, 57600, or 115200 Baud.
Other serial communication parameters are not configurable.
Parity: None; Data bits: 8; Stop Bits: 1; Handshaking: None
Factory default setting: 19200 BAUD
All
Page 63
Seren IPS Inc.
6100220000 Rev. 1.09
Comments to this Manuals