RX01/LX01 SERIES RF POWER SUPPLY OPERATOR’S MANUAL
R101 Specifications Switching Power Supply (P/N 9600600004/9600600005)
AC Mains
Input Power
Voltage Ranges: 98-125V or 198-250V, Single-phase.
Specify desired AC mains voltage range at time of order. Voltage range is
factory configured.
Frequency: 47-63 HZ
Power required: 750VA Maximum
Overcurrent Protection: Rear Panel Circuit Breaker,
2x 3A ¼”x1-1/4” time-delay fuses.
Current: 98-125V: 10A Maximum
198-250V: 5A Maximum
Inrush Current: 36.2A Nominal
Power Cord
Supplied
98-125V Models: 14/3 Type SJT, 2m length, with IEC320-C13 female
connector and NEMA 5-15P male plug.
198-250V Models: 1/3 Type SJT, 2m length, with IEC320-C13 female
connector and NEMA l6-15P male plug.
Output: Power: High Range: 0 to 100 Watts into 50 Ohms
Low Range: 0 to 10 Watts into 50 Ohms
Maximum Reflected
Power:
50 Watts
Frequency: 13.56 MHz, Crystal-Controlled
Leveling: Forward Power, Load (Net) Power,
External Feedback (RF or DC Probe)
Frequency Stability: 0.005% Short-term
Power Stability: 0.5% Long Term
Output Impedance: 50 Ohms, +/-5 Ohms Nominal
Metering Accuracy:
(Forward Power )
+/-3% of Reading
Temperature Coefficient: 0.25% per °C
Forward Power
Regulation:
+/- 1% into 50 Ohms
Load Tolerance: No oscillation or failure into a mismatch
condition.