RX01/LX01 SERIES RF POWER SUPPLY OPERATOR’S MANUAL
PROGRAMMABLE PARAMETER REFERENCE CHART
PARAMETER DISPLAY LINE 3 OPTION Applies To
Pulse Duty Cycle DUTY CYCLE 50 % 0% to 100%,
(Default: 50%)
All models
except
R/L301, R101
(Std and OEM
pulsing)
Set Pulse Source PULSE SET INTERNAL
PULSE SET EXTERNAL
INTERNAL*
EXTERNAL
All
Power Monitor Response MONITOR OUTPUT PEAK
MONITOR OUTPUT REAL
PEAK*
REAL
All
RF Output Ramping
Note: Setting RF Output
Ramping to ON allows
scrolling and setting of
ramping parameters
RAMP MODE OFF
RAMP MODE ON
OFF*
ON
All
RF Output Ramp-Up Time RAMP ON TIME 1S 1S to 9999S,
Variable
(Default: 1S)
All
RF Output Ramp-Down Time RAMP OFF TIME 1S 1S to 9999S,
Variable
(Default: 1S)
All
Leveling Source Select
Note: Setting Leveling Source
to VOLTAGE CONTROL
allows scrolling and setting of
Probe Inversion parameters on
R/L101MKII and
R/L301MKII models
POWER CONTROL
VOLTAGE CONTROL
Internal Power
Sensor*,
External
Feedback
Voltage
All
Probe Inversion VLT CNTRL +PRB DB25
VLT CNTRL -PRB BNC
Probe Inverter
Disabled*
Probe Inverter
Enabled
R/L101MKII
R/L301MKII
Only
Analog Voltage Range Select RANGE 5V F.S.
RANGE 10V F.S.
5VDC*
10VDC
All
Power Leveling Select FWD POWER LEVELING
LOAD POWER LEVELING
Forward Power*
Load (Net)
Power
All
Output Power Range Select HIGH RANGE
LOW RANGE
0-Rated Power*
0-10% Rated
Power
All
Exciter Mode (Frequency
Source) Select
EXCITER- MASTER
EXCITER- SLAVE
Internal Source*
External CEX
Input
All
Maximum Output Power ENTER MAX POWER XXXXXW 1W to Rated
Powe
All
Page 57
Seren IPS Inc.
6100220000 Rev. 1.09