SEREN R301 Operator's Manual Page 96

  • Download
  • Add to my manuals
  • Print
  • Page
    / 210
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 95
RX01/LX01 SERIES RF POWER SUPPLY OPERATOR’S MANUAL
ANALOG INTERFACE CONNECTOR PIN LIST
PIN SIGNAL NAME DESCRIPTION
4 PWR/VLT* Power or Voltage leveling mode select. TTL – compatible input
with internal pull-up resistor.
An open circuit or TTL “high” signal applied to pin 4 selects the
power supply’s internal power sensor for power regulation.
A contact closure between pin 4 and pin 16 or a TTL “low” signal
applied to pin 4 selects forward power regulation based on an
external feedback signal (FEEDBACK signal - Pin 12).
Refer to the controls section of the operator’s manual for
detailed instructions on how to configure and use this mode.
This signal is active only in “Analog” control mode.
5 SLAVE* Selects internal oscillator/exciter or external oscillator/exciter
(Slave Mode) as frequency source operation. TTL – compatible
input with an internal pull-up resistor.
A contact closure between pin 5 and pin 17 or applying a TTL
“low” signal to pin 5 selects external frequency source (Slave
Mode) operation. The external frequency source is connected
to the “CEX IN” connector on the rear panel.
An open circuit or TTL “high” applied to pin 5 selects the power
supply’s internal oscillator/exciter as the frequency source.
This signal is active only in “Analog” control mode.
6 GATEN* Selects Continuous Wave (CW) or Pulse Operation. TTL –
compatible input with an internal pull-up resistor.
A contact closure between pin 6 and pin 17 or applying a TTL
“low” signal to pin 6 selects pulse operation. Apply the external
pulse train to Pin 7.
Applying a logic level high to this pin or allowing this pin to float
selects continuous wave (CW) operation.
7 GATE External Pulse Train input. Toggles output power between
setpoint value and 0 Watts. TTL - compatible input with internal
pull-up resistor.
An open circuit or TTL “high” signal applied to pin 7 holds the RF
output to the setpoint level.
A contact closure between pin 7 and pin 17 or a TTL ‘low” signal
applied to pin 7 switches the RF output power to 0 Watts.
Active when pin 6 (GATEN*) is in a TTL “low” state.
8 RFENABLED* RF output status signal. Active low, open collector output.
24VDC, 15mA maximum current sink, 150mW maximum power
dissipation.
Signal output is 0V (low) for an RF on condition; signal output is
“open” for an RF off condition.