RX01/LX01 SERIES RF POWER SUPPLY OPERATOR’S MANUAL
Safety Notes
POINT
EQUIPOTENTIAL BONDING
!
GROUND
=
PROTECTIVE
= CAUTION
=
HIGH
VOLTAGE
=
RADIO FREQUENCY
ENERGY HAZARD
=
Seren IPS Inc. RF Power Supplies have been designed and tested to meet strict safety
requirements. These include independent lab examination and approval, and compliance to
established standards. Please read the following instructions carefully before operating the RF
Power Supply and refer to them as needed to ensure the continued safe operation of the RF
Power Supply.
Follow all warnings and instructions marked on or supplied with the product.
Symbology:
Unplug or disconnect this equipment from the power source before cleaning or re-configuring
the AC mains voltage.
Do not use this equipment near water, wet locations, or outdoors.
Do not place this equipment on an unstable cart, stand, or table. The RF Power Supply may fall,
causing personal injury or damage to the RF Power Supply.
This product is equipped with a power cord and grounding type plug. This is a safety feature.
To avoid electric shock, this unit must be connected to the power source in compliance with the
National Electrical Code ANSI C1 and/or any other codes applicable to the user. Improper
installation may result in a shock or fire hazard.
It is the responsibility of the installer to provide a proper protective ground from the RF Power
Supply to earth ground, in accordance with local and national electrical codes, and any other
codes applicable to the user.
The RF Power Supply should be operated from the type of power source indicated by the ratings
plate. If you are not sure of the type of power available, consult an electrician or your local
power company.
The power supply cord and plug is the disconnect device for this equipment. If the plug is
removed from the cord and the power cord is hard wired to the power source, it is the
responsibility of the installer to provide a disconnect device.
Do not allow anything to rest on the power cord or interconnecting cables. Do not locate the RF
Power Supply where persons will step on the power or interconnecting cables.
Slots and Openings in the equipment’s chassis are provided for ventilation. To ensure reliable
operation of the RF Power Supply, these openings must not be blocked, covered, or restricted.
Restricting the air inlets or exhaust will cause the unit to overheat. Sustained over temperature
conditions may degrade or damage the unit.