SEREN R301 Operator's Manual Page 138

  • Download
  • Add to my manuals
  • Print
  • Page
    / 210
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 137
RX01/LX01 SERIES RF POWER SUPPLY OPERATOR’S MANUAL
L301MKII Specifications
90-140VAC or 190-264VAC (universal input), Single Phase.
There are no transformer taps to configure.
AC mains voltage specified at time of order determines supplied power cord
Frequency: 47-63 HZ
Power required: 750VA Maximum
Current: 90-140V: 10A Maximum
190-264V: 5A Nominal
Inrush Current: 35A Maximum
Power Cord
Supplied
90-140V Applications: 14/3 Type SJT, 2m length, with IEC320-C13 female
connector and NEMA 5-15P male plug.
190-264V Applications: 1/3 Type SJT, 2m length, with IEC320-C13 female
connector and NEMA l6-15P male plug.
Output: Power: High Range: 0 to 300 Watts into 50 Ohms
Low Range: 0 to 30 Watts into 50 Ohms
Maximum Reflected
Power:
50 Watts
Frequency: 100KHz to 460KHz, 1 KHz steps,
Frequency Synthesized.
Leveling: Forward Power, Load (Net) Power,
External Feedback (RF or DC Probe)
Frequency Stability: 0.005% Short-term
Power Stability: 0.5% Long Term
Output Impedance: 50 Ohms, +/-5 Ohms Nominal
Metering Accuracy:
(Forward Power)
+/-3% of Reading
Temperature Coefficient: 0.25% per °C
Forward Power
Regulation:
+/- 1% into 50 Ohms
Load Tolerance: No oscillation or failure into a mismatch
condition.
AC Mains
Input Power
Overcurrent Protection: Rear Panel Circuit Breaker, 10A
2x 3A ¼”x1-1/4” time-delay fuses.
Page 130
Seren IPS Inc.
6100220000 Rev. 1.09
Page view 137
1 2 ... 133 134 135 136 137 138 139 140 141 142 143 ... 209 210

Comments to this Manuals