SEREN R301 Operator's Manual Page 177

  • Download
  • Add to my manuals
  • Print
  • Page
    / 210
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 176
RX01/LX01 SERIES RF POWER SUPPLY OPERATOR’S MANUAL
L3001 Specifications
Voltage: 190-264V. Single Phase or Three Phase (specify at time of order)
There are no transformer voltage taps to configure.
AC Mains
Input Power
Frequency: 47-63 HZ
Current:
10/3 Type SOW, 6 foot length, with NEMA Type
L6-30P locking connector
Load Tolerance:
Single Phase: 25A Maximum
Three Phase: 25A Maximum
Power required: 5700VA Maximum
Overcurrent Protection: Rear Panel Circuit Breaker,
2x 1.5A ¼”x1-1/4” time-delay fuses.
Power Cord: Single Phase:
Three Phase: 12/4 Type SOW, 6 foot length, with NEMA Type
L15-30P locking connector
Output: Power: High Range: 0 to 3000 Watts into 50 Ohms
Low Range: 0 to 300 Watts into 50 Ohms
Maximum Reflected
Power:
200 Watts
Frequency: 100-460KHz, 1 KHz Steps,
Frequency Synthesized.
Leveling: Forward Power, Load (Net) Power,
External Feedback (RF or DC Probe)
RF Output Connector: Type HN, or 7/16 DIN female. Customer
Specified
Frequency Stability: 0.005% Short-term
Power Stability: 0.5% Long Term, +/- 1 Watt
Output Impedance: 50 Ohms, +/-5 Ohms Nominal
Metering Accuracy:
(Forward Power)
+/- 3% of Reading
Temperature Coefficient: 0.25% per °C
Forward Power
Regulation:
+/- 1% into 50 Ohms
No oscillation or failure into a mismatch
condition.
Page 169
Seren IPS Inc.
6100220000 Rev. 1.09
Page view 176
1 2 ... 172 173 174 175 176 177 178 179 180 181 182 ... 209 210