RX01/LX01 SERIES RF POWER SUPPLY OPERATOR’S MANUAL
R601 Specifications
Voltage: 90-125V or 190-264V (universal input), Single Phase.
There are no transformer voltage taps to configure.
AC mains voltage specified at time of order determines supplied power cord
AC Mains
Input Power
Frequency: 47-63 HZ
Current: 15A Maximum.
Power:
Power required: 1360VA Maximum
Overcurrent Protection: Rear Panel Circuit Breaker,
2x 1.5A ¼”x1-1/4” time-delay fuses.
Power Cord
Supplied
(specified at
time of order)
90-125V: 14/3 Type SJT, 2m length, with IEC320-C13 female connector to
NEMA 5-15P plug. Seren P/N 4500910000
190-264V: 14/3 Type SJT, 2m length, with IEC320-C13 female connector to
NEMA L6-15P plug. Seren P/N 4500910001
Output: High Range: 0 to 600 Watts into 50 Ohms
Low Range: 0 to 60 Watts into 50 Ohms
Maximum Reflected
Power:
100 Watts
Frequency: 13.56 MHz, Fixed.
Leveling: Forward Power, Load (Net) Power,
External Feedback (RF or DC Probe)
Frequency Stability: 0.005% Short-term
Power Stability: 0.5% Long Term, +/- 1 Watt
Output Impedance: 50 Ohms, +/-5 Ohms Nominal
Metering Accuracy:
(Forward Power)
+/- 3% of Reading
Temperature Coefficient: 0.25% per °C
Forward Power
Regulation:
+/- 1% into 50 Ohms
Load Tolerance: No oscillation or failure into a mismatch
condition.
Protection: Forward power limits on current, transistor power
dissipation, and excessive reflected power. Unit
is short-circuit and open-circuit protected. Unit is
thermally protected.
Page 133