RX01/LX01 SERIES RF POWER SUPPLY OPERATOR’S MANUAL
R10001 (27MHz) Specifications
Waste Heat into Coolant
Water
7000 Watts (398 BTU/minute) maximum.
Note: The waste heat does not peak at 8000 Watts
of output power - the waste heat peaks at 50% to
80% of full power or under certain reflected
power conditions.
Interlocks: External: External interlock provided for disabling RF
output power
Valve (optional): Prevents/disables RF Power output if external
water valve is missing or un plugged. (standard
units ignore this interlock – consult factory if
valve interlock is required)
Interface
Connections:
Analog Interface: 25 pin Female D-Sub Connector
Serial Interface:
9 pin Female D-Sub Connector
CEX Input: Female type BNC connector, 3 to 8V Peak-to-
Peak sine wave, 27.12MHz, 50 Ohms Nominal
Impedance
CEX Output: Female type BNC connector, 5 to 8V Peak-to-
Peak, 27.12MHz, into 50 Ohms
VALVE 4-Pin Male Disk-Drive Connector
Power
Monitor
Scaling:
Forward Power Monitor Monitor output is linearly proportional to 0 to
8000 Watts of forward power.
Output scaling is 5.0VDC at 8000 Watts
(0.625mV/Watt) or 10.0VDC at 8000 Watts
(1.25mV/Watt), depending on the analog voltage
range selected. (Default scaling)
Reflected Power Monitor Monitor output is linearly proportional to 0 to 800
Watts of reflected power.
Output scaling is 5.0VDC at 800 Watts
(6.25mV/Watt) or 10.0VDC at 800 Watts
(12.5mV/Watt), depending on the analog voltage
range selected. (Default scaling)
Page 179
Seren IPS Inc.
6100220000 Rev. 1.09