WRITE PACKET WORD DEFINITIONS
WORD2: Operating Frequency (applies to Variable Frequency units only)
MSB LSB
[B15 XXXXXXX] [XXXXXXX B0]
B15 through B0 Operating frequency, in KHz. Variable Frequency units
only. Ignored by Fixed frequency units
WORD3: Control Bits
MSB LSB
[XXXXX B10 B9 B8] [B7 B6 B5 B4 B3 B2 B1 B0]
B10, B9: Control Mode B10=0, B9=0 Panel Control
B10=0, B9=1 Analog Control
B10=1, B9=0 Serial Control
B8: Pulse Mode B8=0 Pulse Off
B8=1 Pulse On
B7: Reserved B7: Reserved
B6: Power/Voltage Control B6=0 Power Control
B6=1 Voltage Control
B5: Analog Range B5=0 Range 5V
B5=1 Range 10V
B4: Leveling B4=0 Forward Power Leveling
B4=1 Load Power Leveling
B3: Power Range B3=0 High Range
B3=1 Low Range
B2: CEX Mode B2=0 Master
B2=1 Slave
B1: Match Preset Enable/Disable B1=0 Match Preset Disabled
B1=1 Match Preset Enabled