RX01/LX01 SERIES RF POWER SUPPLY OPERATOR’S MANUAL
PROGRAMMABLE PARAMETER DETAILS
PARAMETER PARAMETER DETAIL APPLIES TO
power metering resolution.
Factory default setting: HIGH RANGE
Exciter Mode
(Frequency Source)
Select:
EXCITER- MASTER: The unit uses its internal frequency source
to generate the RF output signal. In “master” mode, the internal
frequency source is available at the CEX OUT connector on the
rear panel.
EXCITER- SLAVE: The unit uses the rear panel CEX IN signal
as the frequency source for the RF output signal. “Slave” Mode is
used in systems with multiple RF power supplies; with one RF
power supply as the master and the other power supplies operating
as “slaves”. This configuration is used to keep the power supplies
synchronized, thus preventing or minimizing RF circulating
currents within the processing system. In “slave” mode, the CEX
IN signal is routed to the rear panel CEX OUT connector.
Factory default setting: EXCITER - MASTER
All
Maximum Output
Power:
Allows the user limit the maximum RF output power. Limit is
adjustable between 1 Watt and rated output power, in 1-Watt
increments. When the output power setpoint is equal to the MAX
POWER value, “MAX” is indicated on the front panel display,
line 2, right-hand side.
Factory default setting: Rated Output Power.
All
Source Menu
Enable/Disable
Enables display of the Source Parameter menu options. When set
to “ON”, the Source Parameters are displayed as the next steps in
the menu. Users may scroll the source parameters with the menu
UP/DOWN buttons and adjustments to the settings may be
preformed. When set to “OFF”, the Source Parameters are not
displayed and pressing the menu UP/DOWN buttons skips over
the source parameters.
The Source Parameters do not have any direct effect on the
operation or performance of the RF Power Supply. The Source
Parameter data is stored within the unit’s non-volatile memory, for
retrieval by commands sent to the unit via the serial interface.
Refer to the Serial Interface Operation section for serial command
details.
Factory default setting: SOURCE MENU ENABLED
Custom OEM
Configurations
Start Power Parameter Start Power recallable parameter. Variable, 1W to rated output
power, in 1-Watt increments.
Use the serial command “CGP?” to read the current parameter
value. Refer to the Serial Commands section for a detailed
explanation of the “CGP?” command.
Related menu item: Source Menu Enable/Disable
Factory default setting: 80W
Custom OEM
Configurations
Idle Power Parameter Idle Power recallable parameter. Variable, 1W to rated output
i1
Wi
Custom OEM
Cf
ii
Page 68