SEREN R301 Operator's Manual Page 30

  • Download
  • Add to my manuals
  • Print
  • Page
    / 210
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 29
RX01/LX01 SERIES RF POWER SUPPLY OPERATOR’S MANUAL
SERIAL COMMAND REFERENCE
TO SEND DESCRIPTION/COMMENT Applies To
Page 22
Seren IPS Inc.
6100220000 Rev. 1.09
Response: <cr>
Set the Process Pulse
duty cycle
XXX_D<cr> XXX is the process pulse duty cycle, 1 to
100%, in 1 % increments. 1 to 3 digits.
Response: <cr>
All models
except
R/L301
Set the Process Pulse
Frequency
XXXX_PR<cr> XXXX is the process pulse frequency, in
Hertz, 1Hz to 1000Hz, in 1Hz increments
Custom
OEM
Config
Set the Process Pulse
high time
XXXX_HT<cr> XXXX is the process pulse high time, in
milliseconds. 1mS to 9999mS.
Response: <cr>
All models
except
R/L301
Set the Process Pulse
High Power Setpoint
XXXXX_HP<cr> XXXX is the process pulse high power
setpoint, in Watts. 1 to 5 digits.
Response: <cr>
All models
except
R/L301
Set the Process Pulse
Low Power Setpoint
XXXXX_LP<cr> XXXX is the process pulse low power
setpoint, in Watts. 1 to 5 digits.
Response: <cr>
R301MKII,
L301MKII
Models only
Enable PULSE mode +P<cr> Enables Process Pulsing
Response: <cr>
All models
except
R/L301
Disable PULSE mode -P<cr> Disables Process Pulsing
Response: <cr>
All models
except
R/L301
Set VFT Coarse Trip
Ratio
XXX_CR<cr> XXX is the (Reflected Power) / (Forward
Power) ratio
Range 1 to 100, 1 to 3 digits
Response: <cr>
1.7-2.1MHz
R-Series
Models
L-Series
Models
Set VFT Coarse
Frequency Step
XXXXX_CF<cr> XXXXX is the coarse frequency step, 1 Hz
to 10,000 Hz, 1 Hz increments, 1 to 5 digits
Response: <cr>
1.7-2.1MHz
R-Series
Models
L-Series
Models
Set VFT Fine Frequency
Step
XXXXX_FF<cr> XXXXX is the fine frequency step, 1 Hz to
10,000 Hz, 1 Hz increments, 1 to 5 digits
Response: <cr>
1.7-2.1MHz
R-Series
Models
L-Series
Models
Set VFT Fine Trip Level XXX_FT<cr> XXX is the reflected power level, in Watts,
1 to 3 digits, where VFT stops attempt to
match the load
Response: <prompt><cr>
1.7-2.1MHz
R-Series
Models
L-Series
Models
Set Maximum VFT
F
XXX_MAXVF<cr> XXX is the maximum frequency the VFT
f
1.7-2.1MHz
R
Si
Page view 29