RX01/LX01 SERIES RF POWER SUPPLY OPERATOR’S MANUAL
PROGRAMMABLE PARAMETER REFERENCE CHART
PARAMETER DISPLAY LINE 3 OPTION Applies To
(Default:
2.1MHz)
1.7-2.1MHz
Minimum Frequency MIN FREQ XXXKHZ 100-460KHz
(Default:
100KHz)
L-Series
MIN FREQ XXXMHZ 1.7-2.1MHz
(Default:
1.7MHz)
R-Series
1.7-2.1MHz
Control Source
Note: Setting the control
source to Serial Control allows
scrolling and setting of serial
parameters
PANEL CONTROL
ANALOG CONTROL
SERIAL CONTROL
PANEL*
ANALOG
SERIAL
All
Serial Interface Protocol MODBUS 2W RTU
MODBUS 4W RTU
RS485-2
RS485-4
RS422
RS232
MODBUS 2W
MODBUS 4W
RS485-4
RS485-2
RS422
RS232*
All
Serial Address ADDRESS # XXX 00-247 All
Serial Baud Rate XXXXX BAUD 115200
57600
38400
19200*
9600
4800
2400
All
Pulse Mode
Note: Setting Pulse Mode to
ENABLED allows scrolling
and setting of pulse
parameters
PULSE MODE ENABLED
PULSE MODE DISABLED
ENABLED
DISABLED*
All models
except
R/L301, R101
Pulse High Power ENTER HI PWR XXXXXW 0 Watts to Rated
Power, Variable
(Default: Rated
Power)
OEM Pulsing
R/L301MKII
only
Pulse Low Power ENTER LO PWR 0W 0 Watts to Rated
Power, Variable
(Default: 0
Watts)
OEM Pulsing
R/L301MKII
only
Pulse Frequency FREQUENCY XXXX Hz 0 Hz to 1,000 Hz All models
Pulse High Time HIGH TIME 5MS 1mS to
9999mS,
Variable,
(Default: 5mS)
OEM Pulsing
R/L301MKII
only
Page 56
Seren IPS Inc.
6100220000 Rev. 1.09