RX01/LX01 SERIES RF POWER SUPPLY OPERATOR’S MANUAL
SERIAL COMMAND DETAILS
COMMAND COMMAND DETAIL APPLIES TO
WWWWW is forward power output, in 1-Watt increments, length: 5
characters, fixed. Leading zeros are replaced with the blank space
character.
XXXXXXX is a 7-character ASCII mapped status string as described
in the R command detail.
S Disable the RF Output
Command: S<cr>
Response: <cr>
All
SERIAL Assert SERIAL control.
Switches control of the unit to the serial interface. Front panel setpoint and
RF ON commands are ignored. Analog Interface Connector signals
RFON* and SETPOINT are ignored.
Note: The RF Power Supply powers-up in the last known control state. It
is advisable to issue the “SERIAL<cr> or “***<cr>” command after a
power down – power up cycle or before beginning a process cycle.
Command: SERIAL<cr>
Response: <cr>
Note: This command has the same function as the (***) command.
All
SF Set Variable Frequency Tuning Strike Frequency
Command: XXX_SF<cr>
L-Series: XXX is the desired strike (start) frequency, in KHz, 100 KHz
to 460KHz,
1.7-2.1MHz R-Series: XXX is the desired strike (start) frequency, in 10
KHz increments, 1.70MHz to 2.10MHz. (omit the decimal)
With Variable Frequency Enabled, the unit’s output frequency defaults
to the Strike Frequency setting when the RF output is enabled. If
reflected power is greater than the Fine Tuning Trip Level (FT
command) the Variable Frequency Tuning feature will automatically
adjust the RF output frequency in an attempt to match the load
(minimize reflected power).
Note: When the Variable Frequency Tuning feature is enabled, the
Strike Frequency overrides the programming menu’s operating
frequency setting.
Related Command: FT
Response: <cr>
1.7-2.1MHz
R-Series
Models
L-Series
Models
SLV Sets the RF Power Supply’s Exciter Mode to “SLAVE”. The RF Power
Supply uses the signal applied to the rear panel CEX IN connector as its
frequency source.
Command: SLV<cr>
Response: <cr>
All
TPS Query the Tune Capacitor Preset position.
The “TPS” command is passed thorough the RF Power Supply to the Seren
IPS Inc. model MC2 Matching Network Controller. The MC2’s response
is
p
assed back throu
g
h the RF Power Su
pp