SEREN R301 Operator's Manual Page 181

  • Download
  • Add to my manuals
  • Print
  • Page
    / 210
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 180
RX01/LX01 SERIES RF POWER SUPPLY OPERATOR’S MANUAL
R5001 Specifications
Voltage: 190-264V. Three Phase
There are no transformer voltage taps to configure.
AC Mains
Input Power
Frequency: 47-63 HZ
Current: 30A Maximum
Power required: 9506VA Maximum
Overcurrent Protection: Rear Panel Circuit Breaker,
2x 1.5A ¼”x1-1/4” time-delay fuses.
Power Cord: 10/4 Type SOW, 6 foot length, with NEMA Type L15-30P locking connector
Output: Power: High Range: 0 to 5000 Watts into 50 Ohms
Low Range: 0 to 500 Watts into 50 Ohms
Maximum Reflected
Power:
500 Watts
Frequency: 13.56MHz, Fixed, Crystal Controlled, or
1.7-2.1MHz, 1 KHz Steps, Frequency
Synthesized
Leveling: Forward Power, Load (Net) Power,
External Feedback (RF or DC Probe)
RF Output Connector: Type 7/16 DIN, or LC female. Customer
Specified
Frequency Stability: 0.005% Short-term
Power Stability: 0.5% Long Term, +/- 1 Watt
Output Impedance: 50 Ohms, +/-5 Ohms Nominal
Metering Accuracy:
(Forward Power)
+/- 3% of Reading
Temperature Coefficient: 0.25% per °C
Forward Power
Regulation:
+/- 1% into 50 Ohms
Load Tolerance: No oscillation or failure into a mismatch
condition.
Protection: Forward power limits on current, transistor power
dissipation, and excessive reflected power. Unit
is short-circuit and open-circuit protected. Unit is
thermally protected.