RX01/LX01 SERIES RF POWER SUPPLY OPERATOR’S MANUAL
PROGRAMMABLE PARAMETER REFERENCE CHART
PARAMETER DISPLAY LINE 3 OPTION Applies To
(Default: Rated
Power)
Source Menu Mode
Note: setting Source Menu
Mode to ON allows
scrolling/setting of Source
parameters
SOURCE MENU OFF
SOURCE MENU ON
OFF*
ON
Custom OEM
Configurations
Start Power Parameter START POWER XXXXW 1W to Rated
Power
(Default: 80W)
Custom OEM
Configurations
Idle Power Parameter IDLE POWER XXXXW 1W to Rated
Power
(Default:50W)
Custom OEM
Configurations
PBN Start I Parameter PBN START I XXXA 1-999 Amps
(Default: 150A)
Custom OEM
Configurations
PWR/Beam Factor Parameter PWR/BEAM FACTOR X 1-6
(Default: 2)
Custom OEM
Configurations
Start Sense V Parameter START SENSE V XXV 0-50 Volts
(Default: 50V)
Custom OEM
Configurations
Start Detect I Parameter START DETECT I 0-50 Amps
(Default 5A)
Custom OEM
Configurations
Start Pulse Voltage Parameter START PULSE V XXXXV 0-1000 Volts
(Default: 1000V)
Custom OEM
Configurations
Power 1 Parameter POWER 1 XXXXW 0W to Rated
Power
(Default: 70W)
Custom OEM
Configurations
Power 2 Parameter POWER 2 XXXXW 0W to Rated
Power
(Default: 120W)
Custom OEM
Configurations
Power 3 Parameter POWER 3 XXXXW 0W to Rated
Power
(Default: 5W)
Custom OEM
Configurations
Power 4 Parameter POWER 4 XXXXW 0W to Rated
Power
(Default: 25W)
Custom OEM
Configurations
Power 5 Parameter POWER 5 XXXXW 0W to Rated
Power
(Default: 25W)
Custom OEM
Configurations
Power 6 Parameter POWER 6 XXXXW 0W to Rated
Power
(Default: 25W)
Custom OEM
Configurations
Excessive RF Voltage
Detection Mode
XRFV MODE ON OFF*
ON
Custom OEM
Configurations
Page 58