Problem Solving
Problem Solving Chart
Front Panel Alarm Messages
The following chart lists common problems and front panel alarm messages that may occur
and the recommended solutions. Follow the suggested solutions until the problem is corrected.
If the problem persists, please contact Seren IPS Inc. customer service or a Seren IPS Inc.
service representative.
Condition Suggested Solution
Front panel display does not
illuminate
Check the power connector – ensure it is properly seated in
the AC Mains power inlet.
Verify rear panel circuit breaker is in the “1” (on) position.
Ensure the Analog Interface Connector is fully seated.
Models R101, L101, R301, L301: ensure the Analog
Interface “MAINS INTLK” circuit is completed – connect
pin 1 to pin 14 on the analog interface connector.
Verify the front panel power switch is in the “1” (on)
position (depressed).
Cannot enable the RF output
by pressing the front panel RF
ON/OFF button
Ensure the Analog Interface Connector is fully seated and
the Analog Interface “INTERLOCK” signal is at a TTL
“low” state – apply a TTL “low” signal to pin 2 of the
Analog Interface Connector or connect pins 2 and 15
together on Analog Interface Connector.
Verify the unit is in “Panel” control mode – check the front
panel display, line 2, left-hand side. “PANEL” should be
displayed. For information on changing control mode, refer
to the “Control Source” heading in the Operation section.
Cannot enable the RF output
by pressing the front panel RF
ON/OFF button, or via the
Analog or Serial Interfaces.
The text “EXT” is shown on
line 2 of the front panel
display
The Analog Interface “INTERLOCK” signal is at a TTL
“HIGH” state – disabling the RF output.
Ensure the Analog Interface Connector is fully seated
Apply a TTL “low” signal to pin 2 of the Analog Interface
Connector or connect pins 2 and 15 together on Analog
Interface Connector.
When in ANALOG control
mode, the RF output power is
erratic and/or fluctuates.
Ensure the Analog Interface connector GROUND RETURN
signal (GNDI, pins 9, 16 and 17) is connected to the system
common ground reference.
Page 107
Seren IPS Inc.
6100220000 Rev. 1.09
Page view 114