RX01/LX01 SERIES RF POWER SUPPLY OPERATOR’S MANUAL
12. Coolant Water IN Port (Water Cooled Models Only)
Fitting Type: 3/8” N.P.T. (tapered) dry-seal, hexagonal female pipe.
Connect the output port of the solenoid water vale to the WATER IN port. Connect the
coolant water supply to the input port of solenoid water valve.
13. Coolant Water OUT Port
(Water Cooled Models Only)
Fitting Type: 3/8” N.P.T. (tapered) dry-seal, hexagonal female pipe.
Connect the coolant water return to the WATER OUT port.
Page 101
Seren IPS Inc.
6100220000 Rev. 1.09
!
I
mportant Note: Install or remove the solenoid water valve i
n
accordance with the water fitting installation or removal methods
outlined in the Installation section.
Improper installation, removal, or over-tightening of water fittings
will damage the water inlet/outlet ports and cause water leaks. The
water leak may be internal and unobserved.
Damage to the water inlet/outlet ports and internal components
resulting from improper fitting installation or removal are no
t
covered by Seren IPS Inc. product warranty.
!
I
mportant Note: Install or remove fittings in accordance with the
water fitting installation or removal methods outlined in the
Installation section.
Improper installation, removal, or over-tightening of water fittings
will damage the water inlet/outlet ports and cause water leaks. The
water leak may be internal and unobserved.
Damage to the water inlet/outlet ports and internal components
resulting from improper fitting installation or removal are no
t
covered by Seren IPS Inc. product warranty.