RX01/LX01 SERIES RF POWER SUPPLY OPERATOR’S MANUAL
Display
The front panel display shows the operational status of the RF Power Supply and provides
legends for the keypad.
Line Description
1 Power Display Line
Displays power setpoint and reflected power when the RF Output is disabled.
Displays forward power (or load power) and reflected power when the RF output
is enabled
2 Status Display Line
Displays the current control source, power control mode, exciter mode and
operational alarms. Operational alarms are displayed on the extreme right side of
the line (see the problem solving section for alarm details).
[CONTOL SOURCE] [POWER CONTROL MODE] [EXCITER MODE] [ALARM]
Control Source:
Panel = Front Panel Control
Analog = Analog Interface
Serial = Serial Interface
Power Control Mode:
PWR = Forward Power Leveling (internal power sensor)
PLS = Pulsing Enabled (internal power sensor)
VLT = Voltage Control (external feedback)
Exciter Mode:
MST = Master (internal frequency source)
SLV = Slave (external frequency source)
3 User Configuration Display Line
In RUN mode:
Blank
In PROGRAM mode:
Displays a programmable parameter and its current setting.
4 Keypad Menu – button legends change depending on mode
LINE 1
LINE 2
LINE 3
LINE 4
SET: 0W REF:
PWR
DOWN
PANEL CONTROL
PGM
PANEL
UP
MST
0W