R301 RF POWER SUPPLY OPERATOR’S MANUAL
When in Slave mode, the R301 RF Power Supply uses the common exciter input as its
frequency source.
7. Fan Exhaust
Keep fan exhaust free of obstructions, dust and dirt.
When the R301 RF Power Supply is mounted in an enclosure or
equipment rack, ensure there is an adequate air intake and hot air exhaust.
Operating the R301 at elevated temperatures or reduced airflow for long
periods of time may degrade its reliability and/or void the warranty.
8. Analog Interface Connector
The analog interface connector is located on the rear panel of the R301 Radio Frequency
Power Supply. Connector type: 25-pin female “D” sub-miniature. Control and status
signals for the RF Power Supply are available on this connector. See the table below for
descriptions of the interface connector signals.
Note:
GND, FWDRET, REFRET, FBRET, and SETRET must be referenced at the
user’s system or the unit will not operate properly
The RF Power Supply responds to input from the Analog interface when ANALOG
control has been selected. The Mains Interlock (pins 1 and 14) and External Interlock
(pins 2 and 15) are active regardless of control method selected.
Asterisk (*) denotes an active-low signal
PIN
SIGNAL NAME DESCRIPTION
1 MAINS INTLK 1 AC Mains Power Interlock. 24VAC current loop, 100 mA
maximum current.
A contact closure between pin 1 and pin 14 is required to allow
AC mains power to engage. An open circuit between pin 1 and
pin 14 disables AC mains power.
!
ANALOG INTERFACE
PIN 25
PIN13
PIN 14
PIN1
Page 36
Seren IPS Inc.
6100130000 Rev. 0.05