R301 RF POWER SUPPLY OPERATOR’S MANUAL
Level Parameter Detail
POWER CONTROL: Uses the R301’s internal power sensor as the feedback source
for regulating the RF output level.
Line 1 of the front panel display indicates forward power
setpoint, in Watts, when the RF output is off, indicates Forward
or Load power when the RF output is enabled.
Line 2 of the front panel display indicates “PWR” when
POWER CONTROL is selected.
(Factory Default Setting)
VOLTAGE CONTROL: Uses the analog interface connector’s FEEDBACK signal (pins
12 and 24) as the feedback source for regulating the RF output
level.
Line 1 of the front panel display indicates the voltage setpoint,
when the RF output is off, indicates Probe Voltage when the RF
output is enabled.
Line 2 of the front panel display indicatesVLT” when
VOLTAGE CONTROL is selected.
Related menu levels: 4, 9
Analog Voltage Range Select:
Selects the Full-Scale voltage for the analog interface’s SETPOINT and FEEDBACK inputs, and
the analog interface’s FWD MON (Forward Power monitor) and REFP MON (Reflected Power
monitor) outputs.
RANGE 5V F.S. Sets +5.0VDC as the full-scale voltage.
(Factory Default Setting)
4
RANGE 10V F.S. Sets +10.0VDC as the full-scale voltage.
Power Leveling Select:
Selects the method used to regulate the unit’s RF output power when Leveling Source Select
(menu level 3) is set to POWER CONTROL.
FWD POWER LEVELING Regulates the RF output power based solely on the
forward power feedback signal. The front panel display
and the analog interface’s FWD MON (forward power
monitor) signal indicate the amount of forward power
delivered to the load. (Factory Default Setting)
5
LOAD POWER LEVELING Regulates the RF output power based on the net power
delivered to the load. (forward power – reflected power
= net power). The front panel display and the analog
interface’s FWD MON (forward power monitor) signal
indicate the amount of net power delivered to the load.
6 Output Power Range Select:
HIGH RANGE sets the unit’s output power range from 0% to 100% of the unit’s rated power
output (300 Watts), with standard power setpoint and power metering resolution. (Factory
Default Setting)
LOW RANGE sets the unit’s output power range from 0% to 10% of the unit’s rated power
output (30 Watts), with enhanced power setpoint and power metering resolution.)